Full Automatic Three Phase Meter Test Bench With ICT For ...

Author: Shirley

Sep. 02, 2024

Full Automatic Three Phase Meter Test Bench With ICT For ...

  • Auto protection of short circuit of voltage, open circuit of current, and overload.

    If you want to learn more, please visit our website.

    Adopt multi-serial port system, realizing the parallel communication of computer and the tested meters( optional)

    Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms

  • 50 300 Water Meter Test Bench Testing DN15`DN50 Cast ...




    Main Characteristics
    1. It has the advantages of combining the static mass method with the standard meter method, sharing water source, test pipeline and control system, simple structure, convenient operation, high detection efficiency, economical and practical, and moderate accuracy, to improve the detection reliability of standard meter in normal operation.
    2. Rational range ratio makes the accuracy of the whole measurement range better than 0.02%.
    3. Using a frequency conversion speed controller, the speed of the pump is stable, improves the stability of the device, and achieves a remarkable energy-saving effect.
    4. Hand-controlled pneumatic meter clamp (safety self-locking), electric drain valve, electronically controlled pneumatic commutator, automatic weighing control, static reading automatic conversion to volume value, in order to achieve computer data processing and printing results, detection process programming control.
    5. The device is divided into DN50-DN150 mm tube-changing type and a set of independent stations to adapt to the detection of various flow meters.

    Product Description

    DN(mm)

    15-50

    Main Pipe (mm)

    50

    Water Meter Diameter(mm)

    15/20/25/32/40/50

    Measuring

    Static Mass Method Static and Standard Meter Method

    Flow Range (m3/h)

    6~500

    Flow rate(m/s)

    (1/)

    Electronic Balance (kg)

    120 600

    Standard Meter(mm)

    50 80 150

    (class 0.2)


    Current Stabilizer(m³)

    2.5

    Water Pump

    37kw 22kw 11kw Hm37m

    Working Pressure(MPa)

    0.2-0.4

    Device Uncertainty (%)K=2

    0.05

    Working Temperature (&#;)

    -95&#; ~ normal temperature

    Working Medium

    clean water

    Device Stability

    tnma contains other products and information you need, so please check it out.

    0.15

    Tested Meters

    4 pieces of meters (one line)

    Product Functions

    Water meter automatic exhaust;

    Automatic pressure test;

    Automatic switching and adjustment of flow rate;

    The test data is uploaded to the server.

    Background data management software's main functions:

    member management;

    Product model information management;

    Order addition, modification, query;

    Yield, pass rate statistics;

    Product test data query;

    Output product test report;

    Workload, business query, statistics.


    Product Features

    Workplace, low environmental demands

    Simple operation and high efficiency

    Stable performance and high detection accuracy

    Modular design for easy maintenance

    Complete supporting software, convenient for data processing and query

    Long-term storage of detection data


    Advantages of products compared with traditional testing

    ----employee training

    Automatic calibration test bench

    After training for half a day to one day, employees can operate on the machine.

    Manual calibration test bench

    The training period for new employees is long, and it takes about two weeks or more to be proficient in operations and calculations.

    ---- Indication error

    Automatic calibration test bench

    Relevant data that needs to be collected for water meter calibration is collected and calculated by relevant sensors.

    Manual calibration test bench

    The test data of the water meter, such as the initial reading and the ending reading, need to be read and recorded manually, which is prone to manual misreading, which will affect the calibration results of the water meter.

    ----data query

    Automatic calibration test bench

    After the verification is completed, the data is automatically uploaded to the server, and the data is stored for a long time. The background service software meets various required information queries, such as: water meter data query corresponding to the serial number, order completion query, test report generation, etc.

    Manual calibration test bench

    The traditional calibration method is generally to manually read the initial reading of the water meter, finish the reading and calculate the result, use a paper calibration record sheet to record the calibration data, and then archive it. In this case, information records are often incomplete, such as Calibration time, order number, model, testing point, calibration time, calibration equipment number, calibrator and other relevant information. Moreover, when the verification data needs to be queried again, it is difficult and heavy workload.




    Are you interested in learning more about Bell-Prover Gas Meter Test Bench? Contact us today to secure an expert consultation!

    47

    0

    Comments

    0/2000

    All Comments (0)

    Guest Posts

    If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

    Your Name:(required)

    Your Email:(required)

    Subject:

    Your Message:(required)

    0/2000